ELECTROMEGNETIC FLOWMETER 6500 MAG PROBE 6510 (INSERTION TYPE)

INTRODUCTION
 
“ TORQUE” make Series 6500 is a new range of Bipolar Pulsed DC Insertion Type Electromagnetic Flow meter. It is suitable for pipes with nominal diameters of 100 mm & above. The Flow meter Is based on Faraday’s law of Electromagnetic Induction.
Series 6500 has excellent accuracy and flow range ability within its class. The meter is suitable for use on wide range of corrosive and aggressive range of conductive liquids.

SALIENT FEATURES
 
• Based on Faraday’s law of electromagnetic induction.
• Suitable for pipe sizes of diameters 100 mm & above
• With or without Integral Transmitter.
• Use of Isolating Ball Valve and Pressure Seal arrangement permits ease of mechanical Insertion and removal without disturbing the flow
• Absolute zero stability and noise elimination due to pulse D.C. excitation
• Measurement independent of liquid properties
• Optional inbuilt potentiometer provides full scale flow rate adjustments.
• Negligible pressure loss.
• Maintenance free design due to absence of any moving parts.
• Display of flow rate directly in user specified engineering units

 

APPLICATIONS
 
• Water Supply Networks
• Chemical and Process Industries
• Pharmaceutical Industry
• Waste- Water Management
• Sugar, Food and Beverages industries
• Effluent Treatment Plants

 

SPECIFICATION
 
Suitable for pipe sizes :DN 100 to DN 2000

Media Conductivity (Min) :10 µS / cm (Consult factory for 5 µS/cm)

Media pressure : Up to 15 15 kg / cm2

Media Temperature (PTFE) :0”-75º C

Ambient Temperature Range :0”-50º C

Material : Pipe : SS 316 (NON – Magnetic )

Wetted Parts : PTFE (Teflon) / SS 316

Electrode : SS/ Hostelry C / Ta / Ti / Pt

Weld in Socket with Flanges : Carbon steel

Connecting Flanges : Carbon steel

Transmitter : Cast aluminum (LM6), Epoxy painted

Mounting : Using a 2” Ball Valve Assembly

Power supply :110 / 240 V AC + 15 %, 50 Hz

Power consumption :20 VA

Cable Gland Entry : ½ “ NPT (F)

Analog Output :4-20 mA / DC / 0-20 mA DC

Pulsed Output (Optional) : Low Pulsed rate output 10 to 36000 pulses per hour

a) Output to drive directly external electromagnetic counter of 12/24 V DC @ 200 ma capacity OR
b) Open Collector output , High pulse rate output 0.5 KHz / 1 KHz/ (Open Collector Output)
Communication port (Optional) :RS – 232 / RS – 485 MODBUSRTU protocol

Maximum load Resistance : 1000

Response time :10 Second

Flow velocity Range :0.3 to 10 m/s)

Ingress Protection : IP – 65 for flow Transmitter and IP-68 for sensor Assembly

LED Display :4 Digit Indication for flow rate and 8 digit indication for
Totaliser programming from keyboard for engineeringUnits

Accuracy : K 2 % of span

For Flow Between 0 to 100% : Refer Error Diagram
Reference Conditions

Power Supply : Nominal

Ambient Temperature : 25º + 2ºc

Load Resistance : 500

Repeatability : + 0.2% of span

Effect of Ambient Temperature : Less than 0.2% per 10ºc

Effect of power supply : Less than 0.1% per 10% Voltage Variation

Effect of Load Resistance : Less than 0.1% of span

 

OPERATIONS
 
Electromagnetic Flowmeters are based on Faraday’s law of Electromagnetic Induction.
In a Electromagnetic Flowmeter, magnetic field is generated by a set of coils. As the conductive liquid passes through the electromagnetic field, an electric voltage is induced in the liquid, which is directly proportional its velocity. This Induced voltage is perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the electrodes Is further processed by the transmitter to give standardized output signal or displayed In appropriate Engineering Units on LED Display.
The flux density of the electromagnetic field In a given Flow meter and the
distance between the electrodes are constant, therefore, the induced voltage is only a function or liquid velocity.

 

Related Products

WATER METER

“TEP” WATER METERDOMESTIC WATER METERSSingle Jet Class A & B, 15mm -20mm (½ ” -¾&r... Continue

ELECTROMEGNETIC FLOWMETER FIX TYPE

ELECTROMEGNETIC FLOWMETER 6400 MAG FLOW 6410 (FULL BORE TYPE)INTRODUCTION “TORQUE” make series 6400 ( ... Continue


Request For Quotation
Location
Grand Bay, Port Louis.,
Port Louis - 11327
Port Louis (Mauritius)
MoTuWeThFrSaSu
Closed
Creative Engineers
All rights reserved - Copyright © 2024 - Powered by
4allBIZ
Request a Call Back!